An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authantication fails. The username is directly concatenated with the comm
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injec
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The SSH Client and SSH Server pages are affected by multiple OS injection vulnerabilities due to missing sanitization of input parameters. An at
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenti
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed wi
An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the
An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The host parameter of the TFTP client in the Filesystem Browser page is not properly sanitized. This can be exploited to escape from the origi
An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The authentication on management pages can be bypassed by appending a specific suffix to the URL and by sending an Authorization header that u
An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command int
EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An a
NetComm NF20MESH routers running firmware R6B031 and earlier contain an authenticated remote code execution vulnerability that allows authenticated attackers to execute arbitrary commands as root by i
An authenticated OS command injection vulnerability exists in the BigPond Cable (BPA) WAN configuration module in TL-WR940N v6 due to improper sanitization of user input. An attacker with administrati
A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manip
An OS Command Injection vulnerability exists in the web-based Traceroute diagnostic utility of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver Web Management Interfa
An authenticated command injection vulnerability exists in the Polycom HDX Series command shell interface accessible over Telnet. The lan traceroute command in the devcmds console accepts unsanitized
ELECOM wireless LAN access point devices contain an OS command injection in processing of username parameter. If processing a crafted request, an arbitrary OS command may be executed. No authenticatio
A security vulnerability has been detected in Edimax BR-6478AC V3 1.0.15. This issue affects the function sub_416898 of the file /boafrm/formDebugDiagnosticRun. The manipulation of the argument host l
RE11S v1.11 was discovered to contain a command injection vulnerability via the L2TPUserName parameter at /goform/setWAN.
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter
A security vulnerability has been detected in Edimax BR-6428NS 1.10. Affected is the function formWlbasic of the file /goform/formWlbasic of the component POST Request Handler. The manipulation of the
Page 1+ Next →