VendorProductsCVEsKEVAvg EPSSWorst Severity
1346158.3%CRITICAL

Related CVEs

46
CVE IDDescriptionSeverityCVSSKEVEPSSPublished
CVE-2026-32842Edimax GS-5008PL firmware version 1.00.54 and prior contain an insecure credential storage vulnerability that allows attackers to obtain administrator credentials by accessing configuration backup files. Attackers can download the config.bin file through fupload.cgi to extract plaintext username and password fields for unauthorized administrative access.HIGH7.110.9%Mar 17, 2026
CVE-2026-32841Edimax GS-5008PL firmware versions 1.00.54 and prior contain an authentication bypass vulnerability that allows unauthenticated attackers to access the management interface. Attackers can exploit the global authentication flag mechanism to gain administrative access without credentials after any user authenticates, enabling unauthorized password changes, firmware uploads, and configuration modifications.CRITICAL9.244.0%Mar 17, 2026
CVE-2026-32840Edimax GS-5008PL firmware version 1.00.54 and prior contain a stored cross-site scripting vulnerability in the system_name_set.cgi script that allows attackers to inject arbitrary script code by manipulating the sysName parameter. Attackers can send a crafted POST request with malicious script payload that executes when management pages including system_data.js are viewed by administrators.MEDIUM5.111.8%Mar 17, 2026
CVE-2026-32839Edimax GS-5008PL firmware version 1.00.54 and prior contain a cross-site request forgery vulnerability that allows remote attackers to perform unauthorized administrative actions by inducing logged-in administrators to visit malicious pages. Attackers can exploit the lack of anti-CSRF tokens and request validation to change passwords, upload firmware, reboot the device, perform factory resets, or modify network configurations.MEDIUM5.111.0%Mar 17, 2026
CVE-2026-32838Edimax GS-5008PL firmware version 1.00.54 and prior use cleartext HTTP for the web management interface without implementing TLS or SSL encryption. Attackers on the same network can intercept management traffic to capture administrator credentials and sensitive configuration data.HIGH8.73.9%Mar 17, 2026
CVE-2026-1972A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.MEDIUM5.544.2%Feb 6, 2026
CVE-2026-1971A vulnerability has been found in Edimax BR-6288ACL up to 1.12. Impacted is the function wiz_WISP24gmanual of the file wiz_WISP24gmanual.asp. Such manipulation of the argument manualssid leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.LOW1.912.8%Feb 6, 2026
CVE-2026-1970A flaw has been found in Edimax BR-6258n up to 1.18. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup. This manipulation of the argument submit-url causes open redirect. The attack can be initiated remotely. The exploit has been published and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.LOW2.016.8%Feb 5, 2026
CVE-2020-37150Edimax EW-7438RPn-v3 Mini 1.27 allows unauthenticated attackers to access the /wizard_reboot.asp page in unsetup mode, which discloses the Wi-Fi SSID and security key. Attackers can retrieve the wireless password by sending a GET request to this endpoint, exposing sensitive information without authentication.HIGH8.748.8%Feb 5, 2026
CVE-2020-37149Edimax EW-7438RPn-v3 Mini 1.27 is vulnerable to cross-site request forgery (CSRF) that can lead to command execution. An attacker can trick an authenticated user into submitting a crafted form to the /goform/mp endpoint, resulting in arbitrary command execution on the device with the user's privileges.MEDIUM5.120.6%Feb 5, 2026
CVE-2020-37125Edimax EW-7438RPn-v3 Mini 1.27 contains a remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary commands through the /goform/mp endpoint. Attackers can exploit the vulnerability by sending crafted POST requests with command injection payloads to download and execute malicious scripts on the device.CRITICAL9.392.7%Feb 5, 2026
CVE-2020-37097Edimax EW-7438RPn 1.13 contains an information disclosure vulnerability that exposes WiFi network configuration details through the wlencrypt_wiz.asp file. Attackers can access the script to retrieve sensitive information including WiFi network name and plaintext password stored in device configuration variables.HIGH8.730.4%Feb 3, 2026
CVE-2020-37096Edimax EW-7438RPn 1.13 contains a cross-site request forgery vulnerability in the MAC filtering configuration interface. Attackers can craft malicious web pages to trick users into adding unauthorized MAC addresses to the device's filtering rules without their consent.MEDIUM5.14.2%Feb 3, 2026
CVE-2025-70161EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.CRITICAL9.897.6%Jan 9, 2026
CVE-2025-15258A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.LOW2.012.6%Dec 30, 2025
CVE-2025-15257A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.MEDIUM5.590.2%Dec 30, 2025
CVE-2025-15256A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.MEDIUM5.586.9%Dec 30, 2025
CVE-2025-14910A vulnerability was detected in Edimax BR-6208AC 1.02. This impacts the function handle_retr of the component FTP Daemon Service. The manipulation results in path traversal. The attack may be launched remotely. The exploit is now public and may be used. Edimax confirms this issue: "This product is no longer available in the market and has been discontinued for five years. Consequently, Edimax no longer provides technical support, firmware updates, or security patches for this specific model. However, to ensure the safety of our remaining active users, we acknowledge this report and will take the following mitigation actions: (A) We will issue an official security advisory on our support website. (B) We will strongly advise users to disable the FTP service on this device to mitigate the reported risk, by which the product will still work for common use. (C) We will recommend users upgrade to newer, supported models." This vulnerability only affects products that are no longer supported by the maintainer.LOW2.135.4%Dec 19, 2025
CVE-2025-14094A flaw has been found in Edimax BR-6478AC V3 1.0.15. The affected element is the function sub_44CCE4 of the file /boafrm/formSysCmd. This manipulation of the argument sysCmd causes os command injection. The attack may be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.LOW2.096.8%Dec 5, 2025
CVE-2025-14093A vulnerability was detected in Edimax BR-6478AC V3 1.0.15. Impacted is the function sub_416990 of the file /boafrm/formTracerouteDiagnosticRun. The manipulation of the argument host results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.LOW2.096.7%Dec 5, 2025