An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The SSH Client and SSH Server pages are affected by multiple OS injection vulnerabilities due to missing sanitization of input parameters. An at
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injec
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed wi
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authantication fails. The username is directly concatenated with the comm
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenti
An issue was discovered in Lantronix EDS3000PS 3.1.0.0R2. The host parameter of the TFTP client in the Filesystem Browser page is not properly sanitized. This can be exploited to escape from the origi
An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command int
A security vulnerability has been detected in Edimax BR-6478AC V3 1.0.15. This issue affects the function sub_416898 of the file /boafrm/formDebugDiagnosticRun. The manipulation of the argument host l
Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific S
An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter
A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manip
A security vulnerability has been detected in Edimax BR-6428NS 1.10. Affected is the function formWlbasic of the file /goform/formWlbasic of the component POST Request Handler. The manipulation of the
A flaw has been found in Edimax BR-6478AC V3 1.0.15. The affected element is the function sub_44CCE4 of the file /boafrm/formSysCmd. This manipulation of the argument sysCmd causes os command injectio
EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An a
A vulnerability was found in Edimax BR-6428NS 1.10. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component POST Request Handler. Performing a manipulation
An authenticated OS command injection vulnerability exists in the BigPond Cable (BPA) WAN configuration module in TL-WR940N v6 due to improper sanitization of user input. An attacker with administrati
A command injection vulnerability has been identified in the Telnet command-line interface (CLI) of TP-Link TL-MR6400 v5.3. This issue is caused by insufficient sanitization of data processed during
Edimax GS-5008PL firmware version 1.00.54 and prior contain a stored cross-site scripting vulnerability in the system_name_set.cgi script that allows attackers to inject arbitrary script code by manip
An OS command injection vulnerability exists in multiple Raidsonic NAS devices—specifically tested on IB-NAS5220 and IB-NAS4220—via the unauthenticated timeHandler.cgi endpoint exposed through the web