A firmware update mechanism in the affected charging controller fails to validate the authenticity of firmware packages delivered through the device's management interface. Because cryptographic signa
Since the firmware update is not validated, an attacker can install modified firmware on the
device. This has a high impact on the availabilty, integrity and confidentiality up to the complete comprom
The firmware update functionality does not verify the authenticity of the supplied firmware update files. This allows attackers to flash malicious firmware update files on the device. Initial analysis
A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file
Deck Mate 2's firmware update mechanism accepts packages without cryptographic signature verification, encrypts them with a single hard-coded AES key shared across devices, and uses a truncated HMAC f
Multiple vulnerabilities in Aqara Hub firmware update process in the Camera Hub G3 4.1.9_0027, Hub M2 4.3.6_0027, and Hub M3 4.3.6_0025 devices, allow attackers to install malicious firmware without p
Reolink Video Doorbell WiFi DB_566128M5MP_W performs insufficient validation of firmware update signatures. This allows attackers to load malicious firmware images, resulting in arbitrary code executi
An issue was discovered in Trusted Firmware-M through 2.0.0. The lack of argument verification in the logging subsystem allows attackers to read sensitive data via the login function.
Since the encryption algorithm used to protect firmware updates is itself encrypted using key material available to an attacker (or anyone paying attention), the firmware updates may be altered by an
Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.
The firmware signature verification is enf
Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations
The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitima
A vulnerability was determined in Belkin AX1800 1.1.00.016. Affected by this vulnerability is an unknown functionality of the component Firmware Update Handler. This manipulation causes insufficient v
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validat
In Package Manager, there is a possible device lock controller bypass due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed
An issue in C-CHIP (com.cchip.cchipamaota) v.1.2.8 allows a remote attacker to obtain sensitive information via the firmware update process.
Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authe
The Semtech LR11xx LoRa transceivers implement secure boot functionality using digital signatures to authenticate firmware. However, the implementation uses a non-standard cryptographic hashing algori