A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection lo
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the us
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations
CVE-2025-11043
CRITICAL CVSS 9.1
Find Similar
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to p
A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks coul
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corru
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already establishe
A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. This product lacks HSTS (HTTP Strict Transport Security) configuration. When an attacker performs a Man in th
CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus
CVE-2024-45032
CRITICAL CVSS 10.0
Find Similar
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validat
FreyrSCADA/IEC-60870-5-104 server v21.06.008 allows remote attackers to cause a denial of service by sending specific message sequences.
An improper certificate validation vulnerability [CWE-295] in FortiNAC-F version 7.2.4 and below may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the HTTPS comm
A vulnerability in the TLS cryptography functionality of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attac
A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (Al
Improper certificate validation in the PAM propagation WinRM connections allows a network attacker to perform a man-in-the-middle attack via disabled TLS certificate verification.
An unauthenticated remote attacker may use an uncontrolled resource consumption in the IEC 61131 program of the affected products by creating large amounts of network traffic that needs to be handled
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonito