Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corru
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the us
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the att
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already establishe
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection lo
An Improper Access Control vulnerability in Advantech SUSI driver (susi.sys) allows attackers to read/write arbitrary memory, I/O ports, and MSRs, resulting in privilege escalation, arbitrary code exe
A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing
A vulnerability was found in 70mai X200 up to 20251019. This issue affects some unknown processing of the component Init Script Handler. The manipulation results in file inclusion. The attack requires
In Thermo Fisher Scientific Xcalibur before 4.7 SP1 and Thermo Foundation Instrument Control Software (ICSW) before 3.1 SP10, the driver packages have a local privilege escalation vulnerability due to
A vulnerability, which was classified as critical, was found in RT-Thread up to 5.1.0. This affects the function sys_device_open/sys_device_read/sys_device_control/sys_device_init/sys_device_close/sys
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonito
The DXE module SmmComputrace contains a vulnerability that allows local attackers to leak stack or global memory. This could lead to privilege escalation, arbitrary code execution, and bypassing OS se
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1
Improper input validation in the UEFI firmware GenerationSetup module for the Intel(R) Server D50DNP and M50FCP boards may allow a privileged user to potentially enable information disclosure via loca