Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue af
Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. Th
Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects Car
Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or ele
Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.
Insecure Direct Object Reference vulnerability in Deporsite from T-INNOVA allows an attacker to retrieve sensitive information from others users via "idUsuario" parameter in "/helper/Familia/establece
Insecure Direct Object Reference vulnerability in Deporsite from T-INNOVA allows an attacker to retrieve sensitive information from others users via "idUsuario" parameter in "/helper/Familia/obtenerFa
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
MedDream WEB DICOM Viewer Cleartext Transmission of Credentials Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected
This vulnerability exists in e-Sushrut due to improper authorization checks during resource access. An authenticated attacker could exploit this vulnerability by manipulating encoded parameters in the
An unauthenticated attacker with access to the local network of the
medical office can query an unprotected Fast Healthcare Interoperability
Resources (FHIR) API to get access to sensitive electroni
Insecure Direct Object Reference (IDOR) in Negotiator v3.15.2 from Biobanking and Biomolecular Resources - European Research Infrastructure (BBMRI-ERIC). This vulnerability allows an attacker to acces
A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such mani
A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoi
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY
The 'Medical History' module in PHPGurukul Hospital Management System v4.0 contains an Insecure Direct Object Reference (IDOR) vulnerability. The application fails to verify that the requested 'viewid