A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
Tenda FH451 v1.0.0.9 has a stack overflow vulnerability located in the RouteStatic function.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function.
A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
A stack overflow in Tenda AX1806 v1.0.0.1 allows attackers to cause a Denial of Service (DoS) via a crafted input.
Tenda AC6 V15.03.05.16 was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
Tenda AX3 firmware v16.03.12.11 contains a stack-based buffer overflow in the formGetIptv function due to improper handling of the citytag stack buffer, which may result in memory corruption and remot
Tenda FH451 v1.0.0.9 has a stack overflow vulnerability in the fromDhcpListClient function.
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a craf
Tenda AC6 v2.0 V15.03.06.50 was discovered to contain a buffer overflow in the function 'formSetPPTPServer'.
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.
Tenda CH22 V1.0.0.6(468) has a stack overflow vulnerability located in the frmL7PlotForm function.
Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime.
In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.