Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
CVE-2025-25668
CRITICAL CVSS 9.8
Find Similar
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function.
CVE-2025-25664
CRITICAL CVSS 9.8
Find Similar
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
CVE-2025-25667
CRITICAL CVSS 9.8
Find Similar
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanSpeed parameter in the fromAdvSetMacMtuWan function.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the mac parameter in the fromAdvSetMacMtuWan function.
Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_42F69C function at /goform/setMacFilterCfg.
Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_43fdcc function at /goform/SetNetControlList.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function.
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanMTU parameter in the fromAdvSetMacMtuWan function.
CVE-2024-57581
CRITICAL CVSS 9.8
Find Similar
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the cloneType parameter in the fromAdvSetMacMtuWan function.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
Tenda AC6 V15.03.05.16 was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
CVE-2024-57579
CRITICAL CVSS 9.8
Find Similar
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
Tenda AX-3 v16.03.12.10_CN was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. This vulnerability allows attackers to cause a Denial of Servi
Page 1+ Next →