Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
CVE-2024-40414
CRITICAL CVSS 9.8
Find Similar
A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVE-2024-40415
CRITICAL CVSS 9.8
Find Similar
A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVE-2024-40416
CRITICAL CVSS 9.8
Find Similar
A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
A vulnerability, which was classified as critical, has been found in Tenda TX3 16.03.13.11_multi. This issue affects some unknown processing of the file /goform/SetNetControlList. The manipulation of
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The man
A vulnerability has been found in Tenda AC20 16.03.08.12. This affects the function set_qosMib_list of the file /goform/SetNetControlList of the component SetNetControlList Endpoint. The manipulation
CVE-2025-29135
CRITICAL CVSS 9.8
Find Similar
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBas
A vulnerability has been found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argu
CVE-2025-52221
CRITICAL CVSS 9.8
Find Similar
Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetCfm function via the funcname, funcpara1, and funcpara2 parameters.
A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component http
A vulnerability was found in Tenda W3 1.0.0.3(2204). Affected by this issue is the function formSetCfm of the file /goform/setcfm of the component HTTP Handler. The manipulation of the argument funcpa
A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer over
A vulnerability was determined in Tenda AC20 16.03.08.12. This issue affects the function sub_48E628 of the file /goform/SetIpMacBind. The manipulation of the argument list leads to stack-based buffer
A vulnerability was identified in Tenda AC20 16.03.08.12. This issue affects the function sub_46A2AC of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-bas
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argum
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation o
Page 1+ Next →