Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi
CVE-2026-40950 is a buffer overflow vulnerability in the Secure Access server prior to 14.50. Attackers with control of a modified client can send a specially crafted message to the server and cause
A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been declared as critical. This vulnerability affects the function ctxz_asp of the file /ctxz.asp of the component Connection Limit Page.
A heap-based buffer overflow vulnerability in the processing of Link Control Protocol messages in FortiGate versions 5.6.12, 6.0.10, 6.2.4 and 6.4.1 and earlier may allow a remote attacker with valid
A vulnerability has been found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_425FF8 of the file /boafrm/formFirewallAdv of the component Advanced Firewall Configuration Endpo
CVE-2024-45162
CRITICAL CVSS 9.8
Find Similar
A stack-based buffer overflow issue was discovered in the phddns client in Blu-Castle BCUM221E 1.0.0P220507 via the password field.
A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07.26A1. This issue affects some unknown processing of the file /menu_nat_more.asp of the component HTTP Request
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password brok
A vulnerability has been found in D-Link DWR-M960 1.01.07. This affects the function sub_4196C4 of the file /boafrm/formVpnConfigSetup of the component VPN Configuration Endpoint. The manipulation of
An issue was discovered in FastNetMon Community Edition through 1.2.7. The sFlow v5 plugin allows remote attackers to cause a denial of service (application crash) via a crafted packet that specifies
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. Th
CVE-2026-11499
CRITICAL CVSS 9.3
Find Similar
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomai
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the arg
A vulnerability was detected in Yealink SIP-T46U 108.87.50.1. The affected element is the function StartReportInformation of the file /api/inner/beforewifitest of the component Web FastCGI Service. Th
Buffer Overflow vulnerability in CDATA FD614GS3-R850 V3.2.7_P161006 (Build.0333.250211) allows an attacker to execute arbitrary code via the node_mac, node_opt, opt_param, and domainblk parameters of
A vulnerability classified as critical was found in TOTOLINK A3002R and A3002RU 3.0.0-B20230809.1615. This vulnerability affects unknown code of the file /boafrm/formFilter of the component HTTP POST
A vulnerability, which was classified as critical, was found in Netgear JWNR2000v2 1.0.0.11. This affects the function sub_41A914. The manipulation of the argument host leads to buffer overflow. The v
A security vulnerability has been detected in Belkin F9K1015 1.00.10. Affected by this vulnerability is an unknown functionality of the file /goform/formConnectionSetting. The manipulation of the argu
A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_46385C of the file /boafrm/formDosCfg. Performing a manipulation of the argument submit-url results in stack-b
Page 1+ Next →