Use of hard coded credentials in GoHarbor Harbor version 2.15.0 and below, allows attackers to use the default password and gain access to the web UI.
CWE-798 Use of Hard-coded Credentials
CWE-798: Use of Hard-coded Credentials
Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker an
A vulnerability was determined in opsre go-ldap-admin up to 20251011. This issue affects some unknown processing of the file docs/docker-compose/docker-compose.yaml of the component JWT Handler. Execu
CWE-1392: Use of Default Credentials
A use of hard-coded credentials vulnerability in Fortinet FortiWeb 7.6.0, FortiWeb 7.4 all versions, FortiWeb 7.2 all versions, FortiWeb 7.0 all versions may allow an authenticated attacker with shell
A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credent
There are several scripts in the web interface that are accessible via undocumented hard-coded credentials. The scripts provide access to additional administrative/debug functionality and are likely i
A use of hard-coded password vulnerability in FortiWLC version 8.5.2 and below, version 8.4.8 and below, version 8.3.3 to 8.3.2, version 8.2.7 to 8.2.6 may allow a local, authenticated attacker to con
Hardcoded credentials in default configuration of PPress 0.0.9.
A hardcoded credential vulnerability exists in a specific deployment pattern for Esri Portal for ArcGIS versions 11.4 and below that may allow a remote unauthenticated attacker to gain administrative
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1)
An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product.
Hard-coded cryptographic keys in Admin UI of EZCast Pro II before version 1.17478.177 allows attackers to bypass authorization checks and gain full access to the admin UI
An issue pertaining to CWE-259: Use of Hard-coded Password was discovered in oslabs-beta ThermaKube master.
An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges.
A CWE-259 "Use of Hard-coded Password" for the root account in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to execute arbitrary code with root privile
Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of