Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
CVE-2026-25786
CRITICAL CVSS 9.3
Find Similar
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authori
CVE-2026-25787
CRITICAL CVSS 9.3
Find Similar
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker wh
CVE-2025-40943
CRITICAL CVSS 9.4
Find Similar
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagno
CVE-2024-44087
CRITICAL CVSS 9.2
Find Similar
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file
CVE-2025-40746
CRITICAL CVSS 9.4
Find Similar
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remo
In Deciso OPNsense before 25.7.4, when creating an "Interfaces: Devices: Point-to-Point" entry, the value of the parameter ptpid is not sanitized of HTML-related characters/strings. This value is dire
CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering workstation when specific driver interface is invoked locally by an authenticated user with cra
The web server of affected devices do not properly authenticate user request to the '/ClientArea/RuntimeInfoData.mwsl' endpoint. This could allow an unauthenticated remote attacker to gain knowledge a
A vulnerability, which was classified as problematic, has been found in Trimble SPS851 488.01. Affected by this issue is some unknown functionality of the component Receiver Status Identity Tab. The m
A vulnerability in the Mitel 6800 Series, 6900 Series, and 6900w Series SIP Phones through 6.4 SP4 (R6.4.0.4006), and the 6970 Conference Unit through 6.4 SP4 (R6.4.0.4006) or version V1 R0.1.0, could
The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication.
Multiple vulnerabilities in the web-based management interface of Cisco Identity Services Engine (ISE) could allow an authenticated, remote attacker with administrative write privileges to conduc
Improper validation of a login parameter may allow attackers to redirect users to malicious websites after authentication. This can lead to various risk including stealing credentials from unsuspectin
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
SmartRobot from INTUMIT does not properly validate a specific page parameter, allowing unautheticated remote attackers to inject JavaScript code to the parameter for Reflected Cross-site Scripting att
A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Server V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally
An unauthenticated attacker with network access to the affected device's web interface can execute any system command via the "msg_events.php" script as the www-data user. The HTTP GET parameter "data
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
CWE-20: Improper Input Validation vulnerability exists that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when a malicious project file is loaded by a us
Page 1+ Next →