The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-a
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a har
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139 and in Ruckus ZoneDirector prior to 10.5.1.0.279, where hard-coded credentials for the ftpuser account
In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessibl
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where a hidden debug script `.ap_debug.sh` invoked
RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build has a hardcoded SSH private key for a root-equivalent user account.
Ruckus Access Point products contain an arbitrary file read vulnerability in the command-line interface that allows authenticated remote attackers with administrative privileges to read arbitrary file
Runtipi is a personal homeserver orchestrator. Starting in version 4.5.0 and prior to version 4.7.2, an unauthenticated Path Traversal vulnerability in the `UserConfigController` allows any remote use
In RUCKUS Network Director (RND) < 4.5.0.56, the OVA appliance contains hardcoded SSH keys for the postgres user. These keys are identical across all deployments, allowing an attacker with network acc
The CloudStack cluster service runs on unauthenticated port (default 9090) that can be misused to run arbitrary commands on targeted hypervisors and CloudStack management server hosts. Some of these c
In RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build, OS command injection can occur via an IP address field provided by an authenticated user.
A remote command injection vulnerability exists in Vacron Network Video Recorder (NVR) devices v1.4 due to improper input sanitization in the board.cgi script. The vulnerability allows unauthenticated
Tinycontrol LAN Controller v3 (LK3) firmware versions up to 1.58a (hardware v3.8) contain a missing authentication vulnerability in the stm.cgi endpoint. A remote, unauthenticated attacker can send cr
An OS command injection vulnerability exists in AVTECH IP camera, DVR, and NVR devices via the PwdGrp.cgi endpoint, which handles user and group management operations. Authenticated users can supply i
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where an authenticated attacker can disable the pas
An information disclosure vulnerability exists in Aquatronica Controller System firmware versions <= 5.1.6 and web interface versions <= 2.0. The tcp.php endpoint fails to restrict unauthenticated acc
An attacker can use an undocumented UART port on the PCB as a side-channel with the user hardcoded credentials obtained from CVE-2025-41692 to gain read access to parts of the filesystem of the device
Tinycontrol LAN Controller v3 LK3 version 1.58a contains an unauthenticated vulnerability that allows remote attackers to download configuration backup files containing sensitive credentials. Attacker
Ruckus Unleashed contains a remote code execution vulnerability in the web-based management interface that allows authenticated remote attackers to execute arbitrary code on the system when gateway mo
The eudskacs.sys driver version 20250328 shipped with EaseUs Todo Backup 1.2.0.1 fails to properly validate privileges for I/O requests (IRP_MJ_READ/IRP_MJ_WRITE) sent to its device object. This allow