Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
WRC-BE36QS-B and WRC-W701-B contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in WebGUI. If exploited, an arbitrary OS command may be
WRC-X3000GS, WRC-X3000GSA, and WRC-X3000GSN contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in Connection Diagnostics page. If a rem
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in WN-7D36QR and WN-7D36QR/UE. If this vulnerability is exploited, an arbitrary OS command may b
WRC-1167GHBK2-S contains a stored cross-site scripting vulnerability in WebGUI. If exploited, an arbitrary script may be executed on the web browser of the user who accessed WebGUI of the product.
Hidden functionality issue exists in WRC-BE36QS-B and WRC-W701-B. If exploited, the product's hidden debug function may be enabled by a remote attacker who can log in to WebGUI.
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating sy
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in +F FS010M versions prior to V2.0.1_1101. If this vulnerability is exploited, an arbitrary OS
CVE-2025-43879
CRITICAL CVSS 9.3
Find Similar
WRH-733GBK and WRH-733GWH contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in the telnet function. If a remote unauthenticated attack
CVE-2024-45252
CRITICAL CVSS 9.8
Find Similar
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-45251
CRITICAL CVSS 9.8
Find Similar
Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-50121
CRITICAL CVSS 9.5
Find Similar
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution when a malicious folder
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat com
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3)
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated
An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78] in FortiADC 7.6.0 through 7.6.1, 7.4.0 through 7.4.6, 7.2.0 through 7.2.7, 7.1.0 th
CVE-2025-48890
CRITICAL CVSS 9.3
Find Similar
WRH-733GBK and WRH-733GWH contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in miniigd SOAP service. If a remote unauthenticated attac
Page 1+ Next →