A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficien
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications are vulnerable to stored Cross-Site Scripting (XSS), allowing an attacker to inject malicio
A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications store user passwords encrypted in its database. Decryption keys are accessible to users wit
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize input for the p
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for
A vulnerability in the API endpoints of Cisco Integrated Management Controller could allow an authenticated, remote attacker to bypass authorization and take actions on a vulnerable system withou
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without au
A vulnerability, which was classified as problematic, was found in 70mai M300 up to 20250611. Affected is an unknown function of the component Web Server. The manipulation leads to improper access con
An Incorrect Authorization vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authentication mechanism allows unauthorized access to protected API e
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.
A vulnerability was detected in Portabilis i-Educar up to 2.10. Affected by this issue is some unknown functionality of the file /unificacao-aluno. Performing manipulation results in improper authoriz
A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP
A vulnerability was found in Portabilis i-Educar up to 2.9.0. It has been declared as critical. This vulnerability affects unknown code of the file /module/Api/pessoa of the component API Endpoint. Th
A broken access control (BAC) vulnerability in the web-based management interface could allow an authenticated remote attacker with low privileges to view sensitive information. Successful exploitatio
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6M
A security vulnerability has been detected in SourceCodester Online Boat Reservation System 1.0. Affected by this vulnerability is an unknown functionality of the component Administrative Endpoint. Th
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could all
A vulnerability was found in Industrial Application Software IAS Canias ERP 8.03. This affects the function doAction of the component RMI Interface. The manipulation of the argument sessionId results
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP20
Page 1+ Next →