A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain im
This vulnerability occurs when the system permits multiple simultaneous
connections to the backend using the same charging station ID. This can
result in unauthorized access, data inconsistency, or
A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credential
This vulnerability allows network-adjacent attackers to compromise transport security on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit th
A vulnerability was determined in Besen BS20 EV Charging Station up to 20260426. This impacts an unknown function of the component Bluetooth Low Energy Handler. Executing a manipulation can lead to we
A security vulnerability has been detected in Besen BS20 EV Charging Station up to 20260426. This affects an unknown part of the component BLE/WiFi. Such manipulation leads to authentication bypass by
A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulatio
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vuln
ChargePoint Home Flex Inclusion of Sensitive Information in Source Code Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected i
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers befor
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vuln
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers befor
Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vuln
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vuln
ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Ch
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers befor
An unauthenticated attacker can obtain EV charger energy consumption information of other users.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iochar
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood:
Page 1+ Next →