Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
CVE-2024-5660
CRITICAL CVSS 9.8
Find Similar
Use of Hardware Page Aggregation (HPA) and Stage-1 and/or Stage-2 translation on Cortex-A77, Cortex-A78, Cortex-A78C, Cortex-A78AE, Cortex-A710, Cortex-X1, Cortex-X1C, Cortex-X2, Cortex-X3, Cortex-X4,
CVE-2025-10263
CRITICAL CVSS 9.1
Find Similar
Arm C1-Ultra, C1-Premium, Neoverse V3 & V3AE, Neoverse V2, Neoverse V1, Neoverse-N2, Neoverse-N1, Cortex-X925, Cortex-X4, Cortex-X3, Cortex-X2, Cortex-X1 & X1C, Cortex-A710, Cortex-A78, A78AE & A78C,
In certain circumstances, an issue in Arm Cortex-A57, Cortex-A72 (revisions before r1p0), Cortex-A73 and Cortex-A75 may allow an adversary to gain a weak form of control over the victim's branch histo
Uncontrolled search path for the FPGA Support Package for the Intel(R) oneAPI DPC++/C++ Compiler software for Windows before version 2024.2 may allow an authenticated user to potentially enable escala
Insufficient control flow management in the Alias Checking Trusted Module for some Intel(R) Xeon(R) 6 processor E-Cores firmware may allow a privileged user to potentially enable escalation of privile
Improper input validation in ARM® Trusted Firmware used in AMD’s Zynq™ UltraScale+™) MPSoC/RFSoC may allow a privileged attacker to perform out of bound reads, potentially resulting in data leakage an
Improper access control in BMC Firmware for the Intel(R) Server Board S2600WF, Intel(R) Server Board S2600ST, Intel(R) Server Board S2600BP, before version 02.01.0017 and Intel(R) Server Board M50CYP
Uncontrolled search path element in some BIOS and System Firmware Update Package for Intel(R) Server M50FCP family before version R01.02.0002 may allow a privileged user to potentially enable escalati
Improper input validation in the Intel(R) Server Board S2600ST Family BIOS and Firmware Update software all versions may allow a privileged user to potentially enable escalation of privilege via local
The Secure Flag passed to Versal™ Adaptive SoC’s Trusted Firmware for Cortex®-A processors (TF-A) for Arm’s Power State Coordination Interface (PSCI) commands were incorrectly set to secure instead of
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 RX Host in version
CVE-2025-41277
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
CVE-2025-41276
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
CVE-2025-41275
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
CVE-2025-41274
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
CVE-2025-41272
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
CVE-2025-41270
CRITICAL CVSS 9.3
Find Similar
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version
Page 1+ Next →