Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only users to gain write access to managed de
Hirschmann Industrial HiVision versions prior to 06.0.07 and 07.0.03 contains an authentication bypass vulnerability in the master service that allows unauthenticated remote attackers to execute arbit
Hirschmann Industrial HiVision versions 05.0.00 through 08.3.01 prior to 08.3.02 contain an arbitrary code execution vulnerability triggered when an administrator opens a maliciously crafted project f
Hirschmann Industrial HiVision version 08.1.03 prior to 08.1.04 and 08.2.00 contains a vulnerability in the execution of user-configured external applications that allows a local attacker to execute a
A Broken Access Control vulnerability in Nagios Network Analyzer 2024R1.0.3 allows low-privilege users with "Read-Only" access to perform administrative actions, including stopping system services and
A vulnerability in the SSH restricted shell interface of the network management services allows improper access control for authenticated read-only users. If successfully exploited, this vulnerability
A vulnerability in an API of Cisco ISE could allow an authenticated, remote attacker with valid read-only credentials to obtain sensitive information, change node configurations, and restart the node.
An attacker with a valid read-only account can bypass Doris MCP Server’s read-only mode due to improper access control, allowing modifications that should have been prevented by read-only restrictions
Hirschmann HiEOS devices versions prior to 01.1.00 contain an authentication bypass vulnerability in the HTTP(S) management module that allows unauthenticated remote attackers to gain administrative a
A vulnerability in the web-based management interface of Cisco ISE could allow an authenticated, remote attacker to obtain sensitive information from an affected device.
This vulnerability exists b
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized c
Missing Authorization vulnerability in Milestone Systems XProtect VMS allows users with read-only access to Management Server to have full read/write access to MIP Webhooks API.
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new SNMP users.
This could allow
Improper access control for some Intel(R) Arc™ & Iris(R) Xe graphics software before version 32.0.101.6077 may allow an authenticated user to potentially enable denial of service via local access.
An authorization bypass through user-controlled key vulnerability affecting 3DSwym in 3DSwymer on Release 3DEXPERIENCE R2024x allows an authenticated attacker to access some unauthorized data.
Authorization Bypass Through User-Controlled Key vulnerability in Im Park Information Technology, Electronics, Press, Publishing and Advertising, Education Ltd. Co. DijiDemi allows Exploitation of Tru
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1
Lack of authorization of the InputManager D-Bus interface in
InputPlumber versions before v0.63.0 can lead to local Denial-of-Service,
information leak or even privilege escalation in the context of t
Improper access control for some Intel(R) Arc™ & Iris(R) Xe graphics software before version 31.0.101.4032 may allow an authenticated user to potentially enable denial of service via local access.