A compromised HMS Networks Cosy+ device could be used to request a Certificate Signing Request from Talk2m for another device, resulting in an availability issue. The issue was patched on the Talk2m production server on April 18, 2024.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to code injection due to improper parameter blacklisting. This is fixed in version 21.2s10 and 22.1s3.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 use a unique key to encrypt the configuration parameters. This is fixed in version 21.2s10 and 22.1s3, the key is now unique per device.
Insecure Permission vulnerability in Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are executing several processes with elevated privileges.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to XSS when displaying the logs due to improper input sanitization. This is fixed in version 21.2s10 and 22.1s3.
Insecure Permissions vulnerability in Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are susceptible to leaking information through cookies. This is fixed in version 21.2s10 and 22.1s3
HMS Industrial Networks
Anybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.