Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Requ
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write
A stack buffer overflow vulnerability exists in the Wincor Nixdorf wnBios64.sys kernel driver (version 1.2.0.0) in the IOCTL handler for code 0x80102058. The vulnerability is caused by missing bounds
Autel MaxiCharger AC Elite Business C50 AppAuthenExchangeRandomNum Stack-Based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbi
A vulnerability was found in GPAC up to 2.5-DEV-rev2167-gcc9d617c0-master. This vulnerability affects the function swf_def_bits_jpeg of the file src/scene_manager/swf_parse.c of the component MP4Box.
CVE-2024-45480
CRITICAL CVSS 9.2
Find Similar
An improper control of generation of code ('Code Injection') vulnerability in the AprolCreateReport component of B&R APROL <4.4-00P5 may allow an unauthenticated network-based attacker to read files f
A vulnerability has been found in TRENDnet TEW-821DAP 1.12B01. This affects an unknown function of the file /www/cgi/ssi of the component Firmware Update. Such manipulation leads to cleartext transmis
A buffer copy without checking size of input ('classic buffer overflow') vulnerability in Fortinet FortiSwitchAXFixed 1.0.0 through 1.0.1 may allow an unauthenticated attacker within the same adjacent
CVE-2026-24465
CRITICAL CVSS 9.3
Find Similar
Stack-based buffer overflow vulnerability exists in ELECOM wireless LAN access point devices. A crafted packet may lead to arbitrary code execution.
A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypt
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX15
CVE-2025-29045
CRITICAL CVSS 9.8
Find Similar
Buffer Overflow vulnerability in ALFA_CAMPRO-co-2.29 allows a remote attacker to execute arbitrary code via the newap_text_0 key value
CVE-2024-43657
CRITICAL CVSS 9.3
Find Similar
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers befor
A vulnerability was found in Netgear EX3700 up to 1.0.0.88. It has been classified as critical. Affected is the function sub_41619C of the file /mtd. The manipulation leads to stack-based buffer overf
A vulnerability has been found in Datacom DM4100 1.3.6.1.4.1.3709. Affected by this issue is some unknown functionality of the component VLAN Page. Such manipulation of the argument VLAN Name leads to
A vulnerability, which was classified as problematic, was found in D-Link DIR-823X 240126/240802. This affects the function set_wifi_blacklists of the file /goform/set_wifi_blacklists of the component
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privil
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privil
Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected install