Syntax: kev:true severity:critical epss:>0.95 vendor:cisco patch:false
Filters
Severity
Exploitation
Data Source
Data Quality
Vendor
CWE — Weakness Type
Clear all
Top 20 matches Showing top matches — use filters or a more specific query to narrow
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulat
A vulnerability was found in D-Link DIR-823X 250416. Affected by this issue is some unknown functionality of the file /goform/set_ac_status. Performing a manipulation of the argument ac_ipaddr/ac_ipst
CVE-2025-5630
CRITICAL CVSS 9.3
Find Similar
A vulnerability has been found in D-Link DIR-816 1.10CNB05 and classified as critical. This vulnerability affects unknown code of the file /goform/form2lansetup.cgi. The manipulation of the argument i
A security flaw has been discovered in D-Link DIR-823X up to 20250416. This affects the function sub_415028 of the file /goform/set_wan_settings. The manipulation of the argument ppp_username results
A vulnerability has been found in D-Link DIR-618 and DIR-605L 2.02/3.02 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /goform/formSetPassword. T
A vulnerability was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. It has been declared as critical. This vulnerability affects unknown code of the file /goform/form2NetSniper.cgi. The manipulatio
A vulnerability was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/form2IPQoSTcAdd of the compon
A weakness has been identified in D-Link DIR-816 1.10CNB05_R1B011D88210. Affected by this vulnerability is the function sub_445E7C of the file /goform/formDMZ.cgi. This manipulation causes command inj
A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/delete_offline_device. Performing manipulation of the argument delvalue results in c
A vulnerability has been found in D-Link DIR-816 1.10CNB05 and classified as critical. Affected by this vulnerability is the function qosClassifier of the file /goform/qosClassifier. The manipulation
A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. Thi
A vulnerability classified as problematic was found in D-Link DIR-618 and DIR-605L 2.02/3.02. This vulnerability affects unknown code of the file /goform/formAdvFirewall of the component Firewall Serv
A security flaw has been discovered in D-Link DIR-816 1.10CNB05. This affects an unknown function of the file /goform/form2RepeaterStep2.cgi of the component goahead. The manipulation of the argument
A vulnerability has been found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/form2Dhcpd.cgi of
A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the file /goform/set_wifi_blacklists. Such manipulation leads to command injection. It is possible to lau
A vulnerability, which was classified as critical, has been found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. This issue affects some unknown processing of the file /goform/form2AddVrtsrv.cgi of the
A weakness has been identified in D-Link DIR-823X 250416. This impacts an unknown function of the file /goform/set_language. Executing a manipulation of the argument langSelection can lead to os comma
A vulnerability was found in D-Link DCS-931L up to 1.13.0. This affects an unknown part of the file /goform/setSysAdmin. The manipulation of the argument AdminID results in os command injection. The a
A vulnerability has been found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This vulnerability affects the function formAdvanceSetup of the file /goform/formAdvanceSetup. The manipulati
CVE-2025-29635
HIGH CVSS 7.2 KEV
Find Similar
A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/set_prohibitin