A vulnerability was identified in D-Link DWR-M960 1.01.07. The affected element is the function sub_41914C of the file /boafrm/formWanConfigSetup of the component WAN Interface Setting Handler. The ma
Spring Boot applications with Actuator can be vulnerable to an "Authentication Bypass" vulnerability when an application endpoint that requires authentication is declared under the path used by the Cl
A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_switch_settings. This manipulation of the argument port causes comma
Netgear EX8000 V1.0.0.126 was discovered to contain a command injection vulnerability via the switch_status function.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: t
A vulnerability was detected in D-Link DAP-2695 2.00RC131. This affects the function fwupdater_main of the file rgbin of the component Firmware Update Handler. Performing manipulation results in os co
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE.
When the REST interface is enabled by the user, and an attacker gains access to
the control network, and user/password brok
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno C
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to e
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to e
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to e
Active! mail 6 BuildInfo: 6.60.05008561 and earlier contains a stack-based buffer overflow vulnerability. Receiving a specially crafted request created and sent by a remote unauthenticated attacker ma
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
A code injection vulnerability in version 0.4.17 or later of the ChromaDB Python project allows an authenticated attacker to run arbitrary code on the server by sending a malicious model repository an
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cab
Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions
A vulnerability was found in GPAC up to 2.5-DEV-rev2167-gcc9d617c0-master. This vulnerability affects the function swf_def_bits_jpeg of the file src/scene_manager/swf_parse.c of the component MP4Box.
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to p
Improper Control of Generation of Code ('Code Injection') vulnerability in Laborator Kalium kalium allows Code Injection.This issue affects Kalium: from n/a through <= 3.25.
Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24.