CVE-2025-66052
HIGH EPSS 67.5%
Published Jan 9, 20265mo ago · Modified Jun 17, 20261w ago
8.6 CVSS 4.0
Published Jan 9, 2026 5mo ago
Last Modified Jun 17, 2026 1w ago
Description
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVSS Details
Base Score
Exploitability
Impact
Vector string
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Attack Vector Network
Attack Complexity Low
Privileges Required High
User Interaction None
Scope X
Threat Intelligence
EPSS Exploit Probability
67.5% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available
Weaknesses 1
CWE-78 OS Command Injection Injection
Affected Products 2
References 1
- cert.pl https://cert.pl/posts/2026/01/CVE-2025-66049
Remediation
No remediation data recorded yet
Check vendor advisories and the NVD entry for patch availability.