CVE-2025-66050
CRITICAL EPSS 25.2%
Published Jan 9, 20265mo ago · Modified Jun 17, 20261w ago
9.3 CVSS 4.0
Published Jan 9, 2026 5mo ago
Last Modified Jun 17, 2026 1w ago
Description
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVSS Details
Base Score
Exploitability
Impact
Vector string
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Attack Vector Network
Attack Complexity Low
Privileges Required None
User Interaction None
Scope X
Threat Intelligence
EPSS Exploit Probability
25.2% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available
Weaknesses 1
CWE-1393
Affected Products 2
References 1
- cert.pl https://cert.pl/posts/2026/01/CVE-2025-66049
Remediation
No remediation data recorded yet
Check vendor advisories and the NVD entry for patch availability.