CVE-2025-5023

HIGH EPSS 11.3%
Published Jul 10, 202511mo ago · Modified Jun 17, 20261w ago
7.1 CVSS 3.1
High
Find Similar
Published Jul 10, 2025 11mo ago
Last Modified Jun 17, 2026 1w ago

Description

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.

CVSS Details

Base Score
7.1
Exploitability
1.6
Impact
5.5
Vector string
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
Attack Vector Adjacent
Attack Complexity High
Privileges Required None
User Interaction None
Scope Unchanged
Confidentiality Low
Integrity High
Availability High

Threat Intelligence

EPSS Exploit Probability
11.3% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available

Weaknesses 1

CWE-798 Use of Hard-coded Credentials Authentication

References 2

Remediation

No remediation data recorded yet

Check vendor advisories and the NVD entry for patch availability.