CVE-2025-40753

MEDIUM EPSS 0.4%
Published Aug 12, 202510mo ago · Modified Jun 17, 20262w ago
6.8 CVSS 4.0
Medium
Find Similar
Published Aug 12, 2025 10mo ago
Last Modified Jun 17, 2026 2w ago

Description

A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.

CVSS Details

Base Score
6.8
Exploitability
Impact
Vector string
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector Local
Attack Complexity Low
Privileges Required Low
User Interaction None
Scope X

Threat Intelligence

EPSS Exploit Probability
0.4% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available

Weaknesses 1

CWE-312

References 1

Remediation

No remediation data recorded yet

Check vendor advisories and the NVD entry for patch availability.