Description

A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to perform an SQL injection attack against an affected device. To exploit this vulnerability, an attacker must have a valid account on the device with the role of Security Approver, Intrusion Admin, Access Admin, or Network Admin. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface of an affected device. A successful exploit could allow the attacker to read the contents of databases on the affected device and also obtain limited read access to the underlying operating system.

CVSS Details

Base Score
6.5
Exploitability
2.8
Impact
3.6
Vector string
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack Vector Network
Attack Complexity Low
Privileges Required Low
User Interaction None
Scope Unchanged
Confidentiality High
Integrity None
Availability None

Threat Intelligence

EPSS Exploit Probability
35.8% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available

Weaknesses 1

CWE-89 SQL Injection Injection

Affected Products 39

VendorProductVersionRange
ciscosecure_firewall_management_center7.0.0any
ciscosecure_firewall_management_center7.0.0.1any
ciscosecure_firewall_management_center7.0.1any
ciscosecure_firewall_management_center7.0.1.1any
ciscosecure_firewall_management_center7.0.2any
ciscosecure_firewall_management_center7.0.2.1any
ciscosecure_firewall_management_center7.0.3any
ciscosecure_firewall_management_center7.0.4any
ciscosecure_firewall_management_center7.0.5any
ciscosecure_firewall_management_center7.0.6any
ciscosecure_firewall_management_center7.0.6.1any
ciscosecure_firewall_management_center7.0.6.2any
ciscosecure_firewall_management_center7.1.0any
ciscosecure_firewall_management_center7.1.0.1any
ciscosecure_firewall_management_center7.1.0.2any
ciscosecure_firewall_management_center7.1.0.3any
ciscosecure_firewall_management_center7.2.0any
ciscosecure_firewall_management_center7.2.0.1any
ciscosecure_firewall_management_center7.2.1any
ciscosecure_firewall_management_center7.2.2any
ciscosecure_firewall_management_center7.2.3any
ciscosecure_firewall_management_center7.2.3.1any
ciscosecure_firewall_management_center7.2.4any
ciscosecure_firewall_management_center7.2.4.1any
ciscosecure_firewall_management_center7.2.5any
ciscosecure_firewall_management_center7.2.5.1any
ciscosecure_firewall_management_center7.2.5.2any
ciscosecure_firewall_management_center7.2.6any
ciscosecure_firewall_management_center7.2.7any
ciscosecure_firewall_management_center7.2.8any
ciscosecure_firewall_management_center7.2.8.1any
ciscosecure_firewall_management_center7.3.0any
ciscosecure_firewall_management_center7.3.1any
ciscosecure_firewall_management_center7.3.1.1any
ciscosecure_firewall_management_center7.3.1.2any
ciscosecure_firewall_management_center7.4.0any
ciscosecure_firewall_management_center7.4.1any
ciscosecure_firewall_management_center7.4.1.1any
ciscosecure_firewall_management_center7.4.2any

References 1

  • sec.cloudapps.cisco.com https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-sql-inject-2EnmTC8v
    Vendor Advisory

Remediation

No remediation data recorded yet

Check vendor advisories and the NVD entry for patch availability.