CVE-2023-39464
NONE EPSS 72.4%
Published May 3, 20242y ago · Modified Jun 17, 20262w ago
Published May 3, 2024 2y ago
Last Modified Jun 17, 2026 2w ago
Description
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Threat Intelligence
EPSS Exploit Probability
72.4% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available
Weaknesses 1
CWE-428
Affected Products 1
| Vendor | Product | Version | Range |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 | any |
References 2
- trianglemicroworks.com https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new
- zerodayinitiative.com https://www.zerodayinitiative.com/advisories/ZDI-23-1032/
Remediation
No remediation data recorded yet
Check vendor advisories and the NVD entry for patch availability.