CVE-2022-0369

HIGH EPSS 81.1%
Published May 7, 20242y ago · Modified Jun 17, 20262w ago
8.8 CVSS 3.1
High
Find Similar
Published May 7, 2024 2y ago
Last Modified Jun 17, 2026 2w ago

Description

Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.

CVSS Details

Base Score
8.8
Exploitability
2.8
Impact
5.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector Network
Attack Complexity Low
Privileges Required Low
User Interaction None
Scope Unchanged
Confidentiality High
Integrity High
Availability High

Threat Intelligence

EPSS Exploit Probability
81.1% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available

Weaknesses 1

CWE-22 Path Traversal Resource Mgmt

Affected Products 1

VendorProductVersionRange
trianglemicroworksscada_data_gateway5.01.01any

References 1

Remediation

No remediation data recorded yet