CVE-2020-10615
HIGH EPSS 83.2%
Published Apr 15, 20206y ago · Modified Jun 17, 20262w ago
7.5 CVSS 3.1
Published Apr 15, 2020 6y ago
Last Modified Jun 17, 2026 2w ago
Description
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
CVSS Details
Base Score
Exploitability
Impact
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Attack Vector Network
Attack Complexity Low
Privileges Required None
User Interaction None
Scope Unchanged
Confidentiality None
Integrity None
Availability High
Threat Intelligence
EPSS Exploit Probability
83.2% percentile
Exploit & Patch Status
No Known Exploit
No Patch Available
Weaknesses 2
CWE-121
CWE-787 Out-of-bounds Write Memory Safety
Affected Products 1
| Vendor | Product | Version | Range |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * | ≥2.41.0213 – ≤4.0.122 |
References 2
- us-cert.gov https://www.us-cert.gov/ics/advisories/icsa-20-105-03
- zerodayinitiative.com https://www.zerodayinitiative.com/advisories/ZDI-20-547/
Remediation
No remediation data recorded yet
Check vendor advisories and the NVD entry for patch availability.