Description

C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter. Attackers can send GET requests to the users_select.php endpoint with crafted SQL payloads to extract sensitive database information including patient records and system credentials.

CVSS Details

Base Score
8.8
Exploitability
Impact
Vector string
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector Network
Attack Complexity Low
Privileges Required None
User Interaction None
Scope X

Threat Intelligence

EPSS Exploit Probability
18.9% percentile
Exploit & Patch Status
Public Exploit Known
No Patch Available

Weaknesses 2

CWE-306 Missing Authentication for Critical Function Authentication
CWE-89 SQL Injection Injection

Affected Products 1

VendorProductVersionRange
gatechcomputing_for_good\'s_basic_laboratory_information_system* ≤3.4

References 2

  • exploit-db.com https://www.exploit-db.com/exploits/46438
    ExploitVDB Entry
  • vulncheck.com https://www.vulncheck.com/advisories/c4g-blis-sql-injection-via-users-select-php
    Third Party Advisory

Remediation

No remediation data recorded yet

Check vendor advisories and the NVD entry for patch availability.